Owner’s Manual #513677 9 F144I2, SF144I2 and SF121I2 Model Machines
B. Install the rear seal o-ring. Lubricate the outside
of the rear seal o-ring with sanitary lubricant.
NOTE
Do not put Petrol-Gel directly onto the auger shaft.
C. Lubricate the inside metal surface of the rear
seal and install it onto the auger shaft. DO NOT
lubricate the outside of the rear auger seal (Fig.
3-8).
D. Lubricate the hex drive end of the auger with a
small amount of spline lubricant. A small container
of spline lubricant is shipped with the machine.
E. Screw the springs onto the studs in the plastic
ights. The springs must be screwed into the
ights completely to provide proper compression.
NOTE
Make sure the rear of the freezing cylinder is clean
and dry before installing the auger shaft. If the
freezing cylinder is dirty or if there is moisture, the
freezing cylinder may leak at the rear seal.
F. Install the two plastic ights onto the rear of the
auger and insert it part way into the freezing
cylinder.
G. Install the remaining plastic ights, push the auger
into the freezing cylinder and rotate slowly until
the auger engages the drive shaft.
H. Apply a thin layer of sanitary lubricant to the inside
and outside of the auger support bushing. Install
the bushing onto the auger support and install the
auger support into the front of the auger. Rotate
the auger support so that one leg of the support
points straight up.
I. Apply a thin layer of sanitary lubricant to the
o-rings on the spigot body and install the spigot
body through the bottom of the front door.
K. Apply a thin lm of sanitary lubricant to the door
seal o-ring and t it into the groove on the rear
of the front door.
M. Place the front door assembly on the mounting
studs and the push front door against the machine
carefully.
N. Secure the front door to the machine by placing
the knobs on the studs and tightening until nger
tight. Do not overtighten. A proper o-ring seal can
be observed through the transparent front door.
O. Thread the agitator onto the blender shaft and
install the clear acrylic splash guard.
3.8 SANITIZING
Sanitizing must be done after the machine is clean and
just before the machine is lled with mix. Sanitizing the
night before is not effective. However, you should always
clean the machine and parts after using it.
NOTE
The United States Department of Agriculture and
the Food and Drug Administration require that all
cleaning and sanitizing solutions used with food
processing equipment be certi ed for this use.
When sanitizing the machine, refer to local sanitary regu-
lations for applicable codes and recommended sanitizing
products and procedures. The frequency of sanitizing
must comply with local health regulations. Mix sanitizer
according to manufacturer’s instructions to provide a 100
parts per million strength solution. Mix sanitizer in quanti-
ties of no less than 2 gallons of 90°F to 110°F (32°C to
43°C) water. Allow sanitizer to contact the surfaces to be
sanitized for 5 minutes. Any sanitizer must be used only
in accordance with the manufacturer’s instructions.
A. Prepare 2 gallons of Stera-Sheen sanitizing
solution following the manufacturer’s instructions.
B. Install the mix inlet regulator into the hopper with
the air tube towards the front of the machine.
NOTE
Do not twist the mix inlet regulator when installing.
Figure 3-9 Mix Inlet Regulator
Position Air
Tube Towards
Front of Machine
Figure 3-8 Lubricate Rear Seal